162 research outputs found
Integrated Laboratory Demonstrations of Multi-Object Adaptive Optics on a Simulated 10-Meter Telescope at Visible Wavelengths
One important frontier for astronomical adaptive optics (AO) involves methods
such as Multi-Object AO and Multi-Conjugate AO that have the potential to give
a significantly larger field of view than conventional AO techniques. A second
key emphasis over the next decade will be to push astronomical AO to visible
wavelengths. We have conducted the first laboratory simulations of wide-field,
laser guide star adaptive optics at visible wavelengths on a 10-meter-class
telescope. These experiments, utilizing the UCO/Lick Observatory's Multi-Object
/ Laser Tomography Adaptive Optics (MOAO/LTAO) testbed, demonstrate new
techniques in wavefront sensing and control that are crucial to future on-sky
MOAO systems. We (1) test and confirm the feasibility of highly accurate
atmospheric tomography with laser guide stars, (2) demonstrate key innovations
allowing open-loop operation of Shack-Hartmann wavefront sensors (with errors
of ~30 nm) as will be needed for MOAO, and (3) build a complete error budget
model describing system performance. The AO system maintains a performance of
32.4% Strehl on-axis, with 24.5% and 22.6% at 10" and 15", respectively, at a
science wavelength of 710 nm (R-band) over the equivalent of 0.8 seconds of
simulation. The MOAO-corrected field of view is ~25 times larger in area than
that limited by anisoplanatism at R-band. Our error budget is composed of terms
verified through independent, empirical experiments. Error terms arising from
calibration inaccuracies and optical drift are comparable in magnitude to
traditional terms like fitting error and tomographic error. This makes a strong
case for implementing additional calibration facilities in future AO systems,
including accelerometers on powered optics, 3D turbulators, telescope and LGS
simulators, and external calibration ports for deformable mirrors.Comment: 29 pages, 11 figures, submitted to PAS
The Infrared Imaging Spectrograph (IRIS) for TMT: the atmospheric dispersion corrector
We present a conceptual design for the atmospheric dispersion corrector (ADC)
for TMT's Infrared Imaging Spectrograph (IRIS). The severe requirements of this
ADC are reviewed, as are limitations to observing caused by uncorrectable
atmospheric effects. The requirement of residual dispersion less than 1
milliarcsecond can be met with certain glass combinations. The design decisions
are discussed and the performance of the design ADC is described. Alternative
options and their performance tradeoffs are also presented.Comment: SPIE Astronomical Instrumentation 201
The infrared imaging spectrograph (IRIS) for TMT: spectrograph design
The Infra-Red Imaging Spectrograph (IRIS) is one of the three first light
instruments for the Thirty Meter Telescope (TMT) and is the only one to
directly sample the diffraction limit. The instrument consists of a parallel
imager and off-axis Integral Field Spectrograph (IFS) for optimum use of the
near infrared (0.84um-2.4um) Adaptive Optics corrected focal surface. We
present an overview of the IRIS spectrograph that is designed to probe a range
of scientific targets from the dynamics and morphology of high-z galaxies to
studying the atmospheres and surfaces of solar system objects, the latter
requiring a narrow field and high Strehl performance. The IRIS spectrograph is
a hybrid system consisting of two state of the art IFS technologies providing
four plate scales (4mas, 9mas, 25mas, 50mas spaxel sizes). We present the
design of the unique hybrid system that combines the power of a lenslet
spectrograph and image slicer spectrograph in a configuration where major
hardware is shared. The result is a powerful yet economical solution to what
would otherwise require two separate 30m-class instruments.Comment: 15 pages, 11 figure
Optical design for the narrow field infrared adaptive optics system (NFIRAOS) petite on the thirty meter telescope
We describe an exploratory optical design for the Narrow Field InfraRed Adaptive Optics (AO) System (NFIRAOS) Petite, a proposed adaptive optics system for the Thirty Meter Telescope Project. NFIRAOS will feed infrared spectrograph and wide-field imaging instruments with a diffraction limited beam. The adaptive optics system will require multi-guidestar tomographic wavefront sensing (WFS) and multi-conjugate AO correction. The NFIRAOS Petite design specifications include two small 60 mm diameter deformable mirrors (DM's) used in a woofer/tweeter or multiconjugate arrangement. At least one DM would be a micro-electromechanical system (MEMS) DM. The AO system would correct a 10 to 30 arcsec diameter science field as well as laser guide stars (LGS's) located within a 60 arcsec diameter field and low-order or tip/tilt natural guide stars (NGS's) within a 60 arcsec diameter field. The WFS's are located downstream of the DM's so that they can be operated in true closed-loop, which is not necessarily a given in extremely large telescope adaptive optics design. The WFS's include adjustable corrector elements which correct the static aberrations of the AO relay due to field position and LGS distance height
Optical design for the narrow field infrared adaptive optics system (NFIRAOS) petite on the thirty meter telescope
We describe an exploratory optical design for the Narrow Field InfraRed Adaptive Optics (AO) System (NFIRAOS) Petite, a proposed adaptive optics system for the Thirty Meter Telescope Project. NFIRAOS will feed infrared spectrograph and wide-field imaging instruments with a diffraction limited beam. The adaptive optics system will require multi-guidestar tomographic wavefront sensing (WFS) and multi-conjugate AO correction. The NFIRAOS Petite design specifications include two small 60 mm diameter deformable mirrors (DM's) used in a woofer/tweeter or multiconjugate arrangement. At least one DM would be a micro-electromechanical system (MEMS) DM. The AO system would correct a 10 to 30 arcsec diameter science field as well as laser guide stars (LGS's) located within a 60 arcsec diameter field and low-order or tip/tilt natural guide stars (NGS's) within a 60 arcsec diameter field. The WFS's are located downstream of the DM's so that they can be operated in true closed-loop, which is not necessarily a given in extremely large telescope adaptive optics design. The WFS's include adjustable corrector elements which correct the static aberrations of the AO relay due to field position and LGS distance height
The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview
We present an overview of the design of IRIS, an infrared (0.85 - 2.5 micron)
integral field spectrograph and imaging camera for the Thirty Meter Telescope
(TMT). With extremely low wavefront error (<30 nm) and on-board wavefront
sensors, IRIS will take advantage of the high angular resolution of the narrow
field infrared adaptive optics system (NFIRAOS) to dissect the sky at the
diffraction limit of the 30-meter aperture. With a primary spectral resolution
of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will
create an unparalleled ability to explore high redshift galaxies, the Galactic
center, star forming regions and virtually any astrophysical object. This paper
summarizes the entire design and basic capabilities. Among the design
innovations is the combination of lenslet and slicer integral field units, new
4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared
wavefront sensors, and a very large vacuum cryogenic system.Comment: 13 pages, SPIE Proceedings 201
HABITAT: A longitudinal multilevel study of physical activity change in mid-aged adults
Purpose. To explore the role of the neighborhood environment in supporting walking Design. Cross sectional study of 10,286 residents of 200 neighborhoods. Participants were selected using a stratified two-stage cluster design. Data were collected by mail survey (68.5% response rate). Setting. The Brisbane City Local Government Area, Australia, 2007. Subjects. Brisbane residents aged 40 to 65 years. Measures. Environmental: street connectivity, residential density, hilliness, tree coverage, bikeways, and street lights within a one kilometer circular buffer from each resident’s home; and network distance to nearest river or coast, public transport, shop, and park. Walking: minutes in the previous week categorized as < 30 minutes, ≥ 30 < 90 minutes, ≥ 90 < 150 minutes, ≥ 150 < 300 minutes, and ≥ 300 minutes. Analysis. The association between each neighborhood characteristic and walking was examined using multilevel multinomial logistic regression and the model parameters were estimated using Markov chain Monte Carlo simulation. Results. After adjustment for individual factors, the likelihood of walking for more than 300 minutes (relative to <30 minutes) was highest in areas with the most connectivity (OR=1.93, 99% CI 1.32-2.80), the greatest residential density (OR=1.47, 99% CI 1.02-2.12), the least tree coverage (OR=1.69, 99% CI 1.13-2.51), the most bikeways (OR=1.60, 99% CI 1.16-2.21), and the most street lights (OR=1.50, 99% CI 1.07-2.11). The likelihood of walking for more than 300 minutes was also higher among those who lived closest to a river or the coast (OR=2.06, 99% CI 1.41-3.02). Conclusion. The likelihood of meeting (and exceeding) physical activity recommendations on the basis of walking was higher in neighborhoods with greater street connectivity and residential density, more street lights and bikeways, closer proximity to waterways, and less tree coverage. Interventions targeting these neighborhood characteristics may lead to improved environmental quality as well as lower rates of overweight and obesity and associated chromic disease
Stereotactic ablative radiotherapy for the comprehensive treatment of 4-10 oligometastatic tumors (SABR-COMET-10): Study protocol for a randomized phase III trial
Background: Stereotactic ablative radiotherapy (SABR) has emerged as a new treatment option for patients with oligometastatic disease. SABR delivers precise, high-dose, hypofractionated radiotherapy, and achieves excellent rates of local control for primary tumors or metastases. A recent randomized phase II trial evaluated SABR in a group of patients with a small burden of oligometastatic disease (mostly with 1-3 metastatic lesions), and found that SABR was associated with benefits in progression-free survival and overall survival. The goal of this phase III trial is to assess the impact of SABR in patients with 4-10 metastatic cancer lesions. Methods: One hundred and fifty-nine patients will be randomized in a 1:2 ratio between the control arm (consisting of standard of care palliative-intent treatments), and the SABR arm (consisting of standard of care treatment + SABR to all sites of known disease). Randomization will be stratified by two factors: histology (Group 1: prostate, breast, or renal; Group 2: all others), and type of pre-specified systemic therapy (Group 1: immunotherapy/targeted; Group 2: cytotoxic; Group 3: observation). SABR is to be completed within 2 weeks, allowing for rapid initiation of systemic therapy. Recommended SABR doses are 20 Gy in 1 fraction, 30 Gy in 3 fractions, or 35 Gy in 5 fractions, chosen to minimize risks of toxicity. The primary endpoint is overall survival, and secondary endpoints include progression-free survival, time to development of new metastatic lesions, quality of life, and toxicity. Translational endpoints include assessment of circulating tumor cells, cell-free DNA, and tumor tissue as prognostic and predictive markers, including assessment of immunological predictors of response and long-term survival. Discussion: This study will provide an assessment of the impact of SABR on clinical outcomes and quality of life, to determine if long-term survival can be achieved for selected patients with 4-10 oligometastatic lesions. Trial registration: Clinicaltrials.gov identifier: NCT03721341. Date of registration: October 26, 2018
- …